Dorsal Distal Radius Safety Lock Plate 2.4 - Straight
Indications:
- Dorsally displaced distal radius fractures.
- Combination of distal radius with carpal and metacarpal fractures.
- Corrective osteotomies.
Plate Features:
- Anatomically contoured Dorsal Distal Radius Safety Lock Plate 2.4 - Straight.
- Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
- stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
- Plate preserves blood supply to soft tissues and bone.
Click to Zoom
No. of Holes |
Stainless Steel |
5 |
SF-125.105 |
6 |
SF-125.106 |
No. of Holes |
TITANIUM |
5 |
Ti-SF-125.105 |
6 |
Ti-SF-125.106 |
Dorsal Distal Radius Safety Lock L-plate 2.4
Indications:
- Dorsally displaced distal radius fractures.
- Combination of distal radius with carpal and metacarpal fractures.
- Corrective osteotomies.
Plate Features:
- Anatomically contoured Dorsal Distal Radius Safety Lock L-plate 2.4.
- Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
- stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
- Plate preserves blood supply to soft tissues and bone.
Click to Zoom
Angle Type |
Head/Shaft Holes |
Stainless Steel |
Right |
2/3 |
SF-126.203R |
Right |
2/4 |
SF-126.204R |
Left |
2/3 |
SF-126.203L |
Left |
2/4 |
SF-126.204L |
Right |
3/3 |
SF-126.303R |
Right |
3/4 |
SF-126.304R |
Left |
3/3 |
SF-126.303L |
Left |
3/4 |
SF-126.304L |
Angle Type |
Head/Shaft Holes |
TITANIUM |
Right |
2/3 |
Ti-SF-126.203R |
Right |
2/4 |
Ti-SF-126.204R |
Left |
2/3 |
Ti-SF-126.203L |
Left |
2/4 |
Ti-SF-126.204L |
Right |
3/3 |
Ti-SF-126.303R |
Right |
3/4 |
Ti-SF-126.304R |
Left |
3/3 |
Ti-SF-126.303L |
Left |
3/4 |
Ti-SF-126.304L |
Dorsal Distal Radius Safety Lock L-plate 2.4 - Oblique
Indications:
- Dorsally displaced distal radius fractures.
- Combination of distal radius with carpal and metacarpal fractures.
- Corrective osteotomies.
Plate Features:
- Anatomically contoured Dorsal Distal Radius Safety Lock L-plate 2.4 - Oblique.
- Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
- stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
- Plate preserves blood supply to soft tissues and bone.
Click to Zoom
Angle Type |
Head/Shaft Holes |
Stainless Steel |
Right |
3/3 |
SF-127.303R |
Right |
3/4 |
SF-127.304R |
Left |
3/3 |
SF-127.303L |
Left |
3/4 |
SF-127.304L |
Angle Type |
Head/Shaft Holes |
TITANIUM |
Right |
3/3 |
Ti-SF-127.303R |
Right |
3/4 |
Ti-SF-127.304R |
Left |
3/3 |
Ti-SF-127.303L |
Left |
3/4 |
Ti-SF-127.304L |
Dorsal Distal Radius Safety Lock T-plate 2.4
Indications:
- Dorsally displaced distal radius fractures.
- Combination of distal radius with carpal and metacarpal fractures.
- Corrective osteotomies.
Plate Features:
- Anatomically contoured Dorsal Distal Radius Safety Lock T-plate 2.4.
- Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
- stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
- Plate preserves blood supply to soft tissues and bone.
Click to Zoom
Head/Shaft Holes |
Stainless Steel |
3/3 |
SF-128.303 |
3/4 |
SF-128.304 |
Head/Shaft Holes |
TITANIUM |
3/3 |
Ti-SF-128.303 |
3/4 |
Ti-SF-128.304 |